Air–water heat pump applied as water boiler in single-family house, coefficient of performance analysis under the real conditions

Authors

DOI:

https://doi.org/10.5604/01.3001.0012.8166

Keywords:

heat pump, air-water, coefficient of performance, COP

Abstract

The subject of the research was an air-water heat pump, model PCUW 2.5kW from HEWALEX, installed in a single-family house. The pump is only used for heating water. The research was carried out from 25-08-2017 to 18-09-2017 in the village of Zborowice, in Malopolska region, Poland. The data were recorded from the heat pump system: temperature of the lower heat source (external air), temperature of the upper heat source (water temperature in the tank), time of heat pump was calculated during the analysed cycle of work and electrical energy consumption. The Coefficient of Performance (COP) of the analysed air-water heat pump was determined. The analysis of the results was carried out using the MATLAB and EXCEL statistical tools. The correlation between COP coefficient and external air temperature is strong: 0.67.

Downloads

Download data is not yet available.

Poppi S, Sommerfeldt N, Bales Ch, Madani H. Techno-economic review of solar heat pump systems for residential heating applications. Renewable and Sustainable Energy Reviews, 2018; 81:22–32.   Google Scholar

Zhao X, Long E, Zhang Y, Liu Q, Jin Z, Liang F. Experimental Study on Heating Performance of Air – source Heat Pump with Water Tank for Thermal Energy Storage. Procedia Engineering, 2017; 205:2055–2062.   Google Scholar

Rubik M. Pompy ciepła w systemach geotermii niskotemperaturowej, MULTICO, Warszawa 2011.   Google Scholar

European Commission. Directive 2010/31/EU on the Energy performance of buildings, 2010.   Google Scholar

Balkea EC, Healyb WM, Ullah T. An assessment of efficient water heating options for an all-electric single family residence in a mixed-humid climate. Energy Build. 2016; 133:371–380.   Google Scholar

HEWALEX catalogue; available: 02-12-2018, at: https://www.hewalex.pl/.   Google Scholar

EKONTROL data collecting system; catalogue, available 05-03-2018 at: https://ekontrol.pl/.   Google Scholar

Water temperature changes (high energy source) under different outside air temperatures (low energy sources) for the analysed air- water heat pump

Downloads

Published

2018-12-27

How to Cite

Lisowska-Lis, A., & Leszczyński, R. (2018). Air–water heat pump applied as water boiler in single-family house, coefficient of performance analysis under the real conditions. Science, Technology and Innovation, 3(2), 58–61. https://doi.org/10.5604/01.3001.0012.8166

Issue

Section

Original articles